Gas fire specifications

 

back to top ↑

Choosing a Gas Convector Fire

The table will help you choose the right fire to fit your fireplace and chimney and heat your room. Where your fireplace opening allows, you may decide fitting a larger fire will look better or give more heat.

When working out which fire you need it is important to remember that your choice will not only depend on a combination of the correct size flue, the fireplace opening and the room size, but what looks best in your room.

Natural and Propane Gas Convector fireplace diagram
 
Fire Size 16″ Natural gas or Propane 18″ Natural gas or Propane 18″ (E) Natural gas only 22″ Natural gas or Propane 22″ Extra Natural gas only 25″ Natural gas only 25″ Extra Natural gas only
Dimensions
mmFrame Width A 453 503 503 600 600 700 700
insFrame Width A 17 ⅞ 19 ¾ 19 ¾ 23 ⅝ 23 ⅝ 27 ½ 27 ½
mmBox Width B 400 450 450 550 550 625 625
insBox Width B 15 ¾ 17 ¾ 17 ¾ 21 ⅝ 21 ⅝ 24 ⅝ 24 ⅝
mmFrame Height C 576 576 576 576 650 576 650
insFrame Height C 22 ⅝ 22 ⅝ 22 ⅝ 22 ⅝ 25 ⅝ 22 ⅝ 25 ⅝
mmBox Height D 554 554 554 554 630 554 630
insBox Height D 21 ⅞ 21 ⅞ 21 ⅞ 21 ⅞ 24 ¾ 21 ⅞ 24 ¾
mmBox Depth E 295 295 295 295 295 295 295
insBox Depth E 11 ⅝ 11 ⅝ 11 ⅝ 11 ⅝ 11 ⅝ 11 ⅝ 11 ⅝
mmBehind Frame F 185 185 185 185 185 185 185
insBehind Frame F 7 ¼ 7 ¼ 7 ¼ 7 ¼ 7 ¼ 7 ¼ 7 ¼
mmRear Box Height G 365 365 365 365 440 365 440
insRear Box Height G 14 ⅜ 14 ⅜ 14 ⅜ 14 ⅜ 17 ⅜ 14 ⅜ 17 ⅜
Fire Size 16″ Natural gas 16″ Propane 18″ Natural gas 18″ (E) Natural gas 18″ Propane 22″ Natural gas 22″ Propane 22″ Extra Natural gas 25″ Natural gas 25″ Extra Natural gas
Fire performance
Input Manual kw 6.85 7.0 9.75 7.0 9.5 11.6 10.8 11.6 11.8 11.8
Input High Remote Control kw 6.85 - 9.75 7.0 - 11.6 - 11.6 12.2 12.2
Output High (2) kw 2.95 2.75 4.35 2.9 3.75 4.8 4.2 4.8 5.1 5.1
Air Supply (1) cm2 20 20 30 20 30 35 35
MK6 Minimum Flue Height m 3.0 - 3.0 3.0 - 3.0 - 4.6 3.0 4.6
MK6 Minimum Flue Diameter mm 125 - 175 175 - 175 - 175 175 175
MK4 Minimum Flue Height m 4.6 4.6 4.6 - 4.6 4.6 4.6 - 4.6 -
MK4 Minimum Flue Diameter mm 175 175 175 - 175 175 175 - 175 -
Notes
  • (1) These appliances mist be installed in accordance with the rules in force and used in a sufficiently ventilated space. Consult your local distributor before installation and use of these appliances.
  • (2) Output figures quoted are approximate only and are Jetmaster laboratory figures (using gross efficiency) and are not part of the CE approval process.
  • = provision for additional ventilation not normally required
  • (E) = Economy
 

back to top ↑

Jetmaster Gas Grates

Model 18″ (S189A) 500 (NU509B) 600 (NU609B) 700 (NU709B)Natural gas only
Dimensions mmA 420 486 586 686
mmB 315 274 274 274
Burner Dimensions  Width 330 330 455 555
 Depth 200 200 200 210
Basket Style Standard De Luxe De Luxe De Luxe
Gas Grate diagram
Notes
  • The gas grates are designed to operate with a minimum flue size of 175mm diameter and a height of at least 4.6 metres. Flues that have been built for a solid fuel fire normally comply with these standards.
  • Gas grates cannot be fitted in low range fires.
  • Air supply to the room should be equivalent to 100cm2.
 
 

back to top ↑

Jetmaster Jetbox

Jetmaster Gas Jetbox diagram
Fire Size 16″ 18″ 16″ 18″
Dimensions mm mm inches inches
Frame Width A 490 540 19 1/4 21 1/4
Frame Height B 586 586 23 23
Box Width C 402 452 15 7/8 17 7/8
Box HeightD 550 550 21 5/8 21 5/8
Box Height (Slope) E 340 340 13 3/8 13 3/8
Box Depth (Top) F 193 193 7 5/8 7 5/8
Box Depth (Behind Frame) G 230 230 9 9
Trim Height 590 590 23 1/4 23 1/4
Trim Width 498 549 19 5/8 21 5/8
Notes
  • (3) = These appliances must be installed in accordance with the rules in force and used in a sufficiently ventilated space. Consult your local distributor before installation and use of these appliances.
  • = provision for additional ventilation not normally required
Fire Size 16″ Natural gas 18″ Natural gas
Dimensions
Input Height kw 7.0 9.75
Outputkw 3.0 4.0
Min. air vent cm2(3) 20
Min. flue height m 3.0 3.0
Min. flue diameter mm 125 (4 ⅞″) 175 (6 ⅞″)
Dimensions
Manual Control
Remote Control
 
 

back to top ↑

Gas Convector Accessories

Fire Size 16″ 18″ 18″ (E) 22″ 22″ Extra 25″ 25″ Extra
  Natural gas Propane Natural gas Propane Natural gas Natural gas Propane Natural gas Natural gas Natural gas
Fronts
Sovereign Black MK6 Burner only
Sovereign Burnished MK6 Burner only
Horizontal Black/Brass or Brushed Steel MK6 Burner only
Basket Black MK6 Burner only
Basket Burnished MK6 Burner only
Regency Black MK4 & MK6 not RC, 18″ only MK6
Regency Burnished MK4 & MK6 not RC, 18″ only MK6
Regular Black MK4 Burner only
Traditional Blacks Brass/Chrome finials MK4 Burner only
Premier MK4 Burner only
Trims
Magnetic Brass
Brushed Stainless Steel