Choosing the right gas fire for your home

Use the following tables to help choose the Jetmaster gas fire that is right for you. Some questions might ask…

  • Do you want a gas fire without a vent?
  • Is your chimney flue Class 1 or Class 2?
  • If you want an inset firebox…
    Do you want convector efficiency (Gas Convector) or not (Jetbox)?
  • If you want a gas grate only…
    Do you have a square opening (Gas Conversion) or a chair brick (Radiant)?

Available sizes

Model Sizes 16″ 18″ 22″ 25″ 500 600 700
Convector
Convector Economy
Convector Extra
Jetbox
Conversion  
Radiant
Radiant Economy

Gas Convector (Natural Gas)

Model 16″ 18″ 18″ Economy 22″ 22″ Extra 25″ 25″ Extra
Input 6.85 kW 9.75 kW 7 kW 11.6 kW 11.8 kW
Output 2.95 kW 4.35 kW 2.9 kW 4.8 kW 5.1 kW
No Vent*
Class 1
Class 2 MK6 only

Jetbox (Natural Gas)

Model 16″ 18″
Input 7 kW 9.75 kW
Output 3 kW 4 kW
No Vent*
Class 1
Class 2

Engine

Each engine supports different features. Use this table to identify what features your gas fire supports.

Features Burner Engine Natural Gas Propane Convective Heat
Convector MK6
Jetbox MK6
Conversion MK4 except 700
Radiant MK6

Legacy

Read the following tables to identify your Jetmaster gas fire. Unfortunately, identifying units by serial numbers is unavailable. We often look underneath the coals to find out what engine we are dealing with, so we can prescribe spares (see "Engines & production years"). Our fires have been marketed with different names over the years, you can look up these names as well as their editions they came in (see "Naming conventions").

Engines & production years

Engine Years Spares available CE marking Identifying factors
MK6 1998–Current Most§ The front set of coals are a pre-formed set, not loose.
MK4 1995–2012 Most Under the coals is vermiculite — a dusty, granular material.
MK2/3 1990–1995 Some Under the coals is a ceramic blanket. This was originally white, like cotton wool but will have blackened with use.
MK1 1986–1993 Few Under the coals is a granular material, like road chippings. This is a volcanic rock called LECA. This unit is lit by match.

Naming conventions

Engine Known as Model Fuel Types Ignition Styles
Open Gas Convectors
MK6 MK6 Gas Convector or Blenheim 16″ Natural Gas Manual / Remote Control / Comfort Control
18″ Economy Natural Gas Manual / Remote Control / Comfort Control
18″ Natural Gas Manual / Remote Control / Comfort Control
22″ Natural Gas Manual / Remote Control / Comfort Control
22″ Extra Natural Gas Manual / Remote Control / Comfort Control
25″ Natural Gas Manual / Remote Control / Comfort Control
25″ Extra Natural Gas Manual / Remote Control / Comfort Control
MK4 Blenheim 16″ Natural Gas / Propane Manual / Comfort Control
16″ Low Natural Gas / Propane Manual / Comfort Control
18″ Natural Gas / Propane Manual / Comfort Control
18″ Low Natural Gas / Propane Manual / Comfort Control
18″ Economy Natural Gas Manual / Comfort Control
22″ Natural Gas / Propane Manual / Comfort Control
25″ Natural Gas / Propane Manual / Comfort Control
MK2 / MK3 MK 3 Gas Convector or MK 2 Gas Convector 16″ Natural Gas / Propane Manual / Comfort Control
16″ Low Natural Gas / Propane Manual / Comfort Control
18″ Natural Gas / Propane Manual / Comfort Control
18″ Low Natural Gas / Propane Manual / Comfort Control
22″ Natural Gas / Propane Manual / Comfort Control
25″ Natural Gas / Propane Manual / Comfort Control
MK1 Homemaker 16″ Natural Gas / Propane Manual
18″ Natural Gas / Propane Manual
22″ Natural Gas / Propane Manual
25″ Natural Gas / Propane Manual
Jetbox Gas Fires (Not Convector)
MK6 Jetbox 16″ Natural Gas Manual / Remote Control / Comfort Control
18″ Natural Gas Manual / Remote Control / Comfort Control
Gas Conversion
MK4 Burghley Universal 500 Natural Gas / Propane Manual / Comfort Control
Universal 600 Natural Gas / Propane Manual / Comfort Control
Universal 700 Natural Gas / Propane Manual / Comfort Control
MK4 Bowhill 16″
18″
22″
25″
MK3 Jewel Gas Grates Standard 16 Natural Gas / Propane Manual / Comfort Control
Standard 18 Natural Gas / Propane Manual / Comfort Control
Universal 500 Natural Gas / Propane Manual / Comfort Control
Universal 600 Natural Gas / Propane Manual / Comfort Control
Universal 700 Natural Gas / Propane Manual / Comfort Control
Extra 700 Natural Gas / Propane Manual / Comfort Control
Extra 850 Natural Gas / Propane Manual / Comfort Control
MK1 Jewel Gas Grates Universal 500 Natural Gas / Propane Manual
Universal 600 Natural Gas / Propane Manual
Universal 700 Natural Gas / Propane Manual
Extra 850 Natural Gas / Propane Manual
Radiant Gas
MK6 Chatsworth 16″Natural Gas Manual
18″Natural Gas Manual
MK4 Chatsworth 16″ Economy Natural Gas / Propane Manual
16″ Natural Gas / Propane Manual
18″ Natural Gas / Propane Manual
MK2 / MK3 MK3 Radiant or MK2 Radiant 16″ Natural Gas / Propane Manual
18″ Natural Gas / Propane Manual
Notes

§ MK6 model with Remote is discontinued. The remote itself is available as a spare.
MK2 and MK3 burner tray is no longer available.
MK1: LECA, trays or gas tubes is not available. MK1 thermocouples and valves are available.
* Provision for vent not normally required.